A113 ◆ SOVEREIGNTY

Sovereign AI Edge Data Center.

Production AI compute on site in 180 days — for military installations and critical infrastructure, integrated with QBOverse data sovereignty.

Request a site assessment
Reference eight-module site: AI Compute, UPS, Power, Generator, Chiller, Buffer Tank, Cooling Tower and Sovereign Ops

180 days*

Turnkey go-live target

< 1.30*

Design PUE target

0.5–50 MW

Modular scalability

01 / The mission edge

AI has to run where the mission and the data already are.

Data can't leave

Operational, patient, criminal-justice, student and grid data carry legal and mission limits on where it may be processed.

The network can't be assumed

Bases, substations, towers and hospitals must keep working when backhaul, cloud regions or timing are degraded or denied.

12–24 months is too slow

Stick-built data centers take 12 to 24 months. Threats, outages and AI adoption do not wait for construction cycles.

A113 Sovereignty puts production AI compute on site in 180 days — owned, governed and auditable by the operator.

02 / The platform

One sovereign stack: edge data center + QBOverse.

LAYER 4

QBOverse Sovereignty

Policy, operator-held keys, provenance, post-quantum encryption

LAYER 3

AI Compute

GPU pods for training, fine-tuning and low-latency inference

LAYER 2

Precision Cooling

Direct-to-chip liquid cooling and chilled hydronics

LAYER 1

Power Infrastructure

MV substation, LFP UPS, standby generation, dual A/B

Owned on site

Compute sits inside the operator's fence line, not in a shared cloud region.

Governed by policy

QBOverse enforces who and what can touch each dataset and model.

Connected by choice

Runs fully disconnected; federates with any cloud only when policy allows.

03 / QBOverse data sovereignty

The operator controls the data — by design.

Residency enforced

Data, models and weights are pinned to the site; egress is blocked unless policy permits it.

Post-quantum ready

Encryption in transit and at rest built on NIST post-quantum standards, with crypto-agility.

Operator-held keys

Keys live in on-site HSMs under the operator's control — not with A113 or any cloud provider.

Provenance & audit

Every query, model version and data access is logged tamper-evident for audit and chain of custody.

Disconnected operations

Full AI capability in DDIL or islanded conditions; sync resumes on reconnection, under policy.

Cloud-agnostic

Federates with commercial, government or peer A113 sites — no lock-in to any AI provider.

04 / Who it serves

Built for military and critical infrastructure.

Military installations

Base AI, ISR fusion, logistics, DDIL ops

Utilities & substations

Grid-edge analytics, outage and wildfire risk

Wireless towers

Edge inference and regional AI points of presence

Hospitals

Imaging AI and clinical LLMs; PHI stays on campus

Law enforcement

Real-time crime center and 911 analytics

School districts

District-owned AI with student data kept local

Water & wastewater

SCADA anomaly detection and asset health

Emergency management

EOC continuity when the grid and network fail

Ports/airports/transit

Security screening and operations analytics

Mission workloads by sector

SectorRepresentative AI workloadsTypical sizeDesigned to support
Military installationsBase-level LLMs, ISR and sensor fusion, predictive maintenance, logistics — in DDIL conditions0.5–5 MW, hardenedNIST SP 800-171, CMMC
Utilities & substationsOutage and DER forecasting, substation video and thermal inspection, wildfire risk0.5–2 MW per site; regional hubsNERC CIP
Wireless towersMulti-access edge inference, RAN optimization, regional AI points of presence0.5–5 MW at aggregation sitesCarrier security baselines
HospitalsImaging AI, ambient clinical documentation, private clinical LLMs on campus0.5–2 MW on campusHIPAA Security Rule
Law enforcementReal-time crime center video analytics, 911/CAD transcription, evidence processing0.5–2 MW per agency or regionFBI CJIS Security Policy
School districtsDistrict-owned AI tutors and staff copilots; campus operations analytics0.5–1 MW shared hubFERPA, COPPA, state privacy laws

Frameworks the architecture is designed to support. Certification and authorization are site- and customer-specific.

05 / Deployment velocity

180 days, not 12 to 24 months.

Traditional benchmark: sequential civil construction, fit-out and on-site integration take 12 to 24 months.

01

Parallel engineering

Site prep and GPU procurement run at the same time, removing serial waits.

02

Factory prefabrication

Power, cooling, busways and telemetry pre-integrated in ISO containers under factory QA/QC.

03

4-week site assembly

Standard hookups let every module be coupled and locked down within 4 weeks of arrival.

04

180-day handover

Operational, sovereign AI data center ready for training and inference workloads.

06 / Reference site

Eight modules, one synchronized site.

Reference eight-module site: AI Compute, UPS, Power, Generator, Chiller, Buffer Tank, Cooling Tower and Sovereign Ops

Power pathUtility MV feed → Power → UPS → AI ComputeGenerator → Power

Thermal loopCooling tower ↔ Chiller ↔ Buffer tank ↔ AI Compute

MonitoringSovereign Ops Center ↔ AI Compute

Reference layout. Site configuration varies.

07 / Modular subsystems

A purpose-built module for every layer.

Chiller container cutaway illustrating the internal equipment arrangement

COOLING

Chiller container

20ft ISO with dual 30 RT air-cooled chillers, duplex pumps and PLC/HMI controls. No cooling tower needed for the base setup.

60 RT combined capacity

Buffer tank container cutaway illustrating the internal equipment arrangement

BUFFER

Buffer tank container

20ft High Cube with a 6-ton SUS-304 stainless reservoir, duplex circulation pumps and redundant container conditioning.

6-ton thermal inertia

AI compute container cutaway illustrating the internal equipment arrangement

COMPUTE

AI compute container

20ft container with 16 B300 nodes, CDU direct-to-chip liquid cooling, 800A DC busway, dual A/B loops and 3D CFD thermal telemetry.

16-node high-density pod

UPS storage container cutaway illustrating the internal equipment arrangement

POWER

UPS storage container

LFP batteries, BMS–UPS–EMS coordination, pack-level aerosol plus FK-5-1-12 clean-agent suppression, >90% efficiency.

Dual-tier fire suppression

Power container cutaway illustrating the internal equipment arrangement

SUBSTATION

Power container

Medium-voltage input, 1000 kVA step-down transformer, VCB/ACB protection, copper busbars and RS485 telemetry.

1000 kVA step-down

Generator container cutaway illustrating the internal equipment arrangement

BACKUP

Generator container

1000 kW diesel standby, multi-generator paralleling controller and a 950 L day tank for about 3.5 hours at full load.

1000 kW standby power

Sovereign Ops Center cutaway illustrating the internal equipment arrangement

OPS & TWIN

Sovereign Ops Center

A113 Twin digital twin, QBOverse console, 85-inch display wall, IoT gateway, 2-second anomaly response and drone/robot dispatch.

Operational in 36 hours

Cooling tower container cutaway illustrating the internal equipment arrangement

HEAT SINK

Cooling tower container

40ft High Cube with VFD pump modulation, proportional two-way valves, expansion tank and DDC automation.

471 kW heat rejection

Voltage, frequency and fuel autonomy are configured to the site's utility standard and mission requirement.

08 / Security & compliance

Defense-in-depth, fence line to model weights.

Physical

Access-controlled ISO modules with tamper sensing and video. Ballistic, EMP/HEMP and seismic hardening scoped per site.

Cyber

Zero-trust segmentation between facility OT and the AI enclave. FIPS 140-3 validated crypto modules; PQC on CNSA 2.0 timelines.

Data

QBOverse residency policy, operator-held keys, tamper-evident provenance and no default telemetry egress.

Supply chain

SBOM, HBOM and origin documentation for every deployment to support NDAA §889, TAA and Buy American reviews.

NIST SP 800-171NIST SP 800-53CMMCNERC CIPCJISHIPAAFERPACNSA 2.0

Frameworks the architecture is designed to support. No certification or authorization is implied; each is pursued per site and customer.

09 / Scale

Building-block scale from site to campus.

0.5–2 MW

Site edge

One compute pod with support modules at a substation, tower aggregation site, hospital campus or installation.

2–5 MW

Regional hub

Multi-pod hub shared by a county, school district, utility region or command — tenants isolated by QBOverse.

5–50 MW

Sovereign campus

Owned or leased AI clusters for state, utility or service-level missions, expanded module by module.

Decoupled add-ons: power or cooling modules alone for existing facilities that need supplemental capacity.

10 / Commercial models

Own it, lease it, or buy outcomes.

Turnkey purchase

Capital acquisition of the full site; operator owns every module and key.

Lease or finance

Operating-budget model with a defined term and refresh path for GPUs.

Sovereign compute as a service

A113 operates on the customer's site; metered per GPU-hour or token, with cost per outcome tracked.

Shared regional capacity

Agencies, hospitals and schools share one hub, each tenant isolated and governed by QBOverse.

Every model includes QBOverse sovereignty, A113 Twin operations and a 24/7 SLA.

11 / Roadmap

Your 180-day sovereign AI roadmap.

01

Assessment & planning

Assess workloads, site power and data-sovereignty requirements; deliver engineering blueprints, ROI and the ownership model.

Phase 1 · Feasibility & ROI

02

Design & factory build

Configure ISO layouts, run concurrent GPU procurement and factory integration, and define QBOverse policy.

Phase 2 · Factory quality build

03

Deployment & go-live

Assemble on site in 4 weeks, configure GPU networks and cybersecurity, run the key ceremony and go live under 24/7 SLA.

Phase 3 · Mission launch

A113 Sovereignty target: operational, sovereign AI infrastructure in 180 days from contract.

12 / Site assessment

Sovereign AI. Mission-ready in 180 days.

Do not submit classified information or Controlled Unclassified Information (CUI). By submitting, you consent to be contacted about your inquiry.

info@a113venture.fund · 202.860.9444 · Dallas, TX

180-day delivery and PUE < 1.30 are design targets. Delivery depends on site readiness, utility interconnection, permitting and GPU allocation. Compliance frameworks listed are those the architecture is designed to support; A113 Sovereignty holds no certification or authorization unless stated for a specific deployment. QBOverse capabilities describe the platform design.